Tuttnauer 2540M Autoclave

Tuttnauer SKU: MEEQ051424001
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave

Tuttnauer 2540M Autoclave

Tuttnauer SKU: MEEQ051424001
Regular price $3,450.00
/
  • Secure payments
  • Low stock - 1 item left
  • Inventory on the way

Don't let the high shipping cost stop you. Contact us to see if we can find a better price.

Shipping calculated at checkout.
Call Us Email Us Text Us WhatsApp

Technical Specifications of the Tuttnauer 2540M Autoclave

Capacity and Chamber Size

  • Volume: 23 liters (6 gallons)
  • Chamber Dimensions: 250 mm diameter x 475 mm depth (10 inches x 19 inches)

This capacity is suitable for small to medium-sized loads, making it ideal for dental offices, small medical practices, and laboratories that require efficient sterilization of instruments and equipment. The Tuttnauer 2540M autoclave offers reliable performance and is perfect for these settings.

Temperature Range

  • Operating temperature ranges from 105°C to 137°C (221°F to 279°F).

These temperatures ensure the destruction of a wide range of microorganisms, including highly resistant bacterial spores. The autoclave operates by using saturated steam to denature proteins and disrupt cellular structures, ensuring effective sterilization.

Pressure Range

  • The working pressure range is approximately 0.7 to 2.5 bar (10.15 to 36.25 psi).

Pressure is a critical component in achieving the necessary high temperatures for sterilization. By increasing the pressure within the chamber, the boiling point of water is raised, allowing the steam to reach higher temperatures and penetrate materials more effectively.

Cycle Types and Control System

  • Manual Operation: Unlike fully automated models, the Tuttnauer 2540M is a manually operated autoclave. Users manually set the temperature and pressure and monitor the cycle duration.
  • Cycle Phases: The autoclave typically runs through phases including heating, sterilizing, and drying. Manual operation requires users to monitor and manage these phases.

Safety Features

  • Automatic Shut-off: The autoclave has a safety shut-off feature that activates at the end of the sterilization cycle to prevent overheating.
  • Safety Valve: Prevents over-pressurization by releasing excess pressure, thereby protecting the system and ensuring user safety.
  • Door Safety Lock: Ensures that the door cannot be opened while the chamber is pressurized, preventing accidents and ensuring safe operation.

Construction

  • Materials: The autoclave is constructed from high-quality stainless steel, which provides resistance to corrosion and ensures durability under high-pressure and high-temperature conditions.
  • Design: The compact design facilitates efficient use of space and ease of operation, with an intuitive loading and unloading process.

Principles of Operation

Sterilization by Saturated Steam

  • Mechanism: The primary sterilization method used by the Tuttnauer 2540M involves saturated steam under pressure. The steam transfers heat to the items within the chamber, and the combination of high temperature and moisture denatures proteins and disrupts cell membranes and DNA, leading to effective sterilization.
  • Temperature and Pressure Correlation: The autoclave operates on the principle that water boils at higher temperatures when under increased pressure. By raising the pressure within the chamber, the boiling point of water (and thus the temperature of the steam) increases, enabling the steam to achieve the necessary conditions for sterilization.

Manual Control System

  • Function: The manual control system requires users to set the temperature and pressure and monitor the cycle duration. Users must manually adjust the settings and monitor the progress of the sterilization cycle.
  • Advantages: Manual control allows for greater flexibility in managing different types of loads and specific sterilization requirements. However, it requires more user involvement and attention compared to automated systems.

Heat Transfer and Moisture Penetration

  • Heat Transfer: Effective sterilization requires uniform heat distribution. The autoclave’s design ensures that steam circulates throughout the chamber, transferring heat to all surfaces of the items being sterilized.
  • Moisture Penetration: Moist heat (steam) is more effective at penetrating materials than dry heat. The steam condenses on cooler surfaces, releasing latent heat and ensuring thorough sterilization of complex instruments and porous materials.

Tuttnauer 2540M Autoclave-Refurbished 

The Tuttnauer 2540M Autoclave is a highly versatile, manually operated sterilization unit, perfect for busy labs and clinics that demand quick instrument turnaround. Its dependable design ensures long-lasting reliability, with a user-friendly control panel that caters to the operator's convenience. Equipped with a durable electro-polished chamber and door, as well as a simple drainage valve for easy reservoir drainage, this autoclave also boasts a dual safety thermostat and automatic shut-off for foolproof protection against overheating. Whether you need to sterilize wrapped or unwrapped instruments, the Tuttnauer 2540M Autoclave has got you covered. With its plug-and-play functionality, it's the ideal solution for healthcare facilities looking to meet all their sterilization needs. This top-of-the-line tabletop autoclave, designed for medical, dental, and laboratory professionals, utilizes pressurized steam to effectively eliminate harmful bacteria, viruses, and other microorganisms. Loaded with a user-friendly control panel

Benefits

  • Sterilizes instruments and equipment quickly and effectively
  • User-friendly design for ease of operation
  • Large chamber capacity for increased productivity
  • Steam under pressure kills a wide range of microorganisms
  • Compact tabletop design saves space in the lab or office.
  • Automatic shut off at the end of both the sterilization and dry cycles
  • Double safety locking device to prevent door opening while chamber is pressurized
  • Dual Safety Thermostat to protect against overheating

Specialty / Medical Practice

General Practice, Dentistry, and more

Importance of Specific Features and Specifications      

  • Product Usage: Instrument Sterilization
  • Brand: Tuttnauer
  • Warranty: 90 days parts and labor only        
  • Dimensions: 21.5" x 20" x 14.4"
  • Voltage:  120V , 50-60 Hz
  • Days to be ready: 1-2 business days. 
  • Manual Operation: The manually operated Tuttnauer 2540M provides flexibility and control over the sterilization process, allowing users to adjust settings as needed. This can be advantageous in settings where specific sterilization parameters are required.
  • Compact Capacity: The 23-liter chamber size is suitable for smaller practices and clinics, providing sufficient space for daily sterilization needs without requiring a large footprint.
  • Safety Measures: Multiple safety features protect both the user and the equipment, making the autoclave reliable and safe to operate in a professional setting.

As a trusted reseller, AngelUS Medical offers the Tuttnauer 2540M Autoclave, providing advanced sterilization technology to medical and laboratory facilities. Our commitment to quality ensures that you receive equipment that is not only advanced and reliable but also backed by exceptional customer support and service.

Equip your facility with the best in sterilization technology through AngelUS Medical, and experience the benefits of high-performance autoclaves that meet the highest standards of safety and efficiency. Choose AngelUS Medical for unparalleled expertise and top-tier Tuttnauer autoclaves.

Related Collections:

Frequently Asked Questions

What is the Tuttnauer 2540M Autoclave used for?

It’s used for sterilizing both wrapped and unwrapped instruments in high volume labs and clinics.

How does the Tuttnauer 2540M Autoclave work?

The autoclave works by using steam under pressure to kill harmful bacteria, viruses, fungi, and spores.

What is the difference between a manual and an automatic autoclave?

A manual autoclave requires the operator to manually set the time and temperature for each cycle, while an automatic autoclave does this automatically.

How accurate is the Tuttnauer 2540M Autoclave?

The Tuttnauer 2540M Autoclave is designed for precision and accuracy to ensure effective sterilization.

Can the Tuttnauer 2540M Autoclave sterilize all types of instruments?

The autoclave can sterilize most types of medical instruments, but certain materials and devices may require special handling.

How often should the Tuttnauer 2540M Autoclave be serviced?

Regular maintenance is essential for the autoclave’s performance and longevity. Please refer to the manufacturer’s guidelines for specific service intervals.

Is the Tuttnauer 2540M Autoclave easy to use?

Yes, the autoclave features an intuitive control panel designed with the operator in mind.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Sold Out
Autoclaves and Sterilizers Autoclaves at Angelus Medical
Autoclaves and Sterilizers
Midmark Ritter
$0.00
Sale
Tuttnauer 3870EA Large Capacity Autoclave Tuttnauer 3870 Large Capacity Autoclave - Tuttnauer -Angelus Medical
Tuttnauer 3870EA Large Capacity Autoclave
Tuttnauer
from $10,500.00 Regular price $11,840.00 Save $1,340
Sale
Midmark Ritter M11 Autoclave Midmark Ritter M11 Autoclave - Midmark Ritter -Angelus Medical
Midmark Ritter M11 Autoclave
Midmark Ritter
from $3,100.00 Regular price $3,750.00 Save $650
Sale
Midmark M9 Autoclave Midmark Ritter M9 UltraClave Autoclave - Midmark Ritter -Angelus Medical
Midmark M9 Autoclave
Midmark Ritter
from $2,200.00 Regular price $2,995.00 Save $795
Sale
Tuttnauer EZ9 Tuttnauer EZ9 Autoclave
Tuttnauer EZ9
Tuttnauer
Sale price $2,750.00 Regular price $2,950.00 Save $200
Tuttnauer 2540M Autoclave Tuttnauer 2540M Autoclave
Tuttnauer 2540M Autoclave
Tuttnauer
$3,450.00
Recently viewed