Oxygen Systems - Angelus Medical and Optical

Oxygen Regulator

31 products

Find out the dependable quality and accuracy of one of the many products we offer the AngelUS Medical Oxygen Regulator. Developed to provide reliability and control, our regulators are precise tools, ideal for professional use as well as for the patient. For oxygen regulators that will put you at ease when it comes to quality, choose AngelUS Medical.

    31 products
    Sale
    Complete Oxygen Tank system Complete Oxygen Tank system (Certified) - NMD -Angelus Medical
    Complete Oxygen Tank system
    NMD
    Sale price $325.00 Regular price $370.00 Save $45
    Sold Out
    Philips Respronics EverFlo Oxygen Concentrator (New) Philips Respronics EverFlo Oxygen Concentrator (New) - Philips -Angelus Medical
    Philips Respronics EverFlo Oxygen Concentrator (New)
    Philips
    $675.00
    Sale
    Oxygen Tank Holder Oxygen Tank Holder (New) - NMD -Angelus Medical
    Oxygen Tank Holder
    CMP
    from $25.00 Regular price $50.00 Save $25
    Sale
    Drive Medical 18112 Deluxe Oxygen Cylinder Rack Drive Medical 18112 Deluxe Oxygen Cylinder Rack (New) - Drive -Angelus Medical
    Drive Medical 18112 Deluxe Oxygen Cylinder Rack
    Drive
    Sale price $55.00 Regular price $60.00 Save $5
    Sold Out
    Oxygen Regulator Oxygen Regulator (New) - Drive -Angelus Medical
    Oxygen Regulator
    Drive
    Sale price $70.00 Regular price $75.00 Save $5
    Allied pressure O2 oxygen regulator (Used) Allied pressure O2 oxygen regulator (Used) - Allied -Angelus Medical
    Allied pressure O2 oxygen regulator (Used)
    Allied
    $130.00
    Sale
    Hudson O2 oxygen regulator (Used) Hudson O2 oxygen regulator (Used) - Medline Industries -Angelus Medical
    Hudson O2 oxygen regulator (Used)
    Medline Industries
    Sale price $45.00 Regular price $95.00 Save $50
    Chemetron oxygen Regulator (Used) Chemetron oxygen Regulator (Used) - Chemetron -Angelus Medical
    Chemetron oxygen Regulator (Used)
    Chemetron
    $55.00
    Sale
    Western Enterprises Oxygen Regulator 2 (Used) Western Enterprises Oxygen Regulator 2 (Used) - Western Medical -Angelus Medical
    Western Enterprises Oxygen Regulator 2 (Used)
    Western Medical
    Sale price $50.00 Regular price $65.00 Save $15
    Western Enterprises Oxygen Regulator 3 (New) Western Enterprises Oxygen Regulator 3 (New) - Western Medical -Angelus Medical
    Western Enterprises Oxygen Regulator 3 (New)
    Western Medical
    $80.00
    Sale
    Hudson OT 408 Oxygen Regulator (USED) Hudson OT 408 Oxygen Regulator (USED) - Medline Industries -Angelus Medical
    Hudson OT 408 Oxygen Regulator (USED)
    Medline Industries
    Sale price $35.00 Regular price $45.00 Save $10
    Oxygen Hose (New) Oxygen Hose (New) - NMD -Angelus Medical
    Oxygen Hose (New)
    NMD
    $40.00
    Sale
    Ohmeda Oxygen Flowmeter (Used) Ohmeda Oxygen Flowmeter (Used) - Datex-Ohmeda -Angelus Medical
    Ohmeda Oxygen Flowmeter (Used)
    Datex-Ohmeda
    Sale price $35.00 Regular price $65.00 Save $30
    Ohio Medical Oxygen Air Flow meter (Used) Ohio Medical Oxygen Air Flow meter (Used) - Ohio -Angelus Medical
    Ohio Medical Oxygen Air Flow meter (Used)
    Ohio
    $40.00
    Sold Out
    Oxygen Tee Connector CGA-870 (NEW) Oxygen Tee Connector CGA-870 (NEW) - Western Medical -Angelus Medical
    Oxygen Tee Connector CGA-870 (NEW)
    Western Medical
    Sale price $45.00 Regular price $50.00 Save $5
    Chemetron Compressed Gas Regulator (Used) Chemetron Compressed Gas Regulator (Used) - NMD -Angelus Medical
    Chemetron Compressed Gas Regulator (Used)
    NMD
    $50.00
    Nitrous Oxide Hose Nitrous Oxide Hose (New) - Angelus Medical and Optical -Angelus Medical
    Nitrous Oxide Hose
    Angelus Medical and Optical
    $70.00
    Nitrus Oxide N2O Regulator Nitrus Oxide N2O Regulator (New) - Nitrus -Angelus Medical
    Nitrus Oxide N2O Regulator
    Nitrus
    $125.00
    Ohio intermittent Suction unit (Used) Ohio intermittent Suction unit (Used) - Ohio -Angelus Medical
    Ohio intermittent Suction unit (Used)
    Ohio
    $39.00
    Ohmeda Intermittent Suction Unit (Used) Ohmeda Intermittent Suction Unit (Used) - Datex-Ohmeda -Angelus Medical
    Ohmeda Intermittent Suction Unit (Used)
    Datex-Ohmeda
    $50.00
    Oxequif Vacuum Regulator (Used) Oxequif Vacuum Regulator (Used) - OXEQUIP -Angelus Medical
    Oxequif Vacuum Regulator (Used)
    OXEQUIP
    $50.00
    Sale
    Timeter Air Flowmeter (Used) Timeter Air Flowmeter (Used) - NMD -Angelus Medical
    Timeter Air Flowmeter (Used)
    NMD
    Sale price $30.00 Regular price $45.00 Save $15
    Sold Out
    Western NO2 Nitrous oxide gas regulator (New) Western NO2 Nitrous oxide gas regulator (New) - Western Medical -Angelus Medical
    Western NO2 Nitrous oxide gas regulator (New)
    Western Medical
    $99.00
    Sale
    Bird Low Air/O2 Blender Bird Low Air/O2 Blender (Used) - Bird -Angelus Medical
    Bird Low Air/O2 Blender
    Bird
    Sale price $500.00 Regular price $650.00 Save $150
    Sale
    Ohmeda Vacuum Regulator - Surgical - Free-Flow (Certified) Ohmeda Vacuum Regulator - Surgical - Free-Flow (Certified) - Datex-Ohmeda -Angelus Medical
    Ohmeda Vacuum Regulator - Surgical - Free-Flow (Certified)
    Datex-Ohmeda
    Sale price $50.00 Regular price $85.00 Save $35
    Sale
    Western Medica Flow meter Carbon Dioxide (Used) Western Medica Flow meter Carbon Dioxide (Used) - Western Medical -Angelus Medical
    Western Medica Flow meter Carbon Dioxide (Used)
    Western Medical
    Sale price $100.00 Regular price $120.00 Save $20
    Sale
    Vacutron full Surgical Vacuum Regulator (Used) - Clearance Vacutron full Surgical Vacuum Regulator (Used) - Clearance - Vacutron -Angelus Medical
    Vacutron full Surgical Vacuum Regulator (Used) - Clearance
    Vacutron
    Sale price $35.00 Regular price $99.00 Save $64

    Principles of Oxygen Regulation

    Oxygen regulators are devices that control the flow of oxygen from a high-pressure source (like a cylinder) to a lower, usable pressure. The main principle behind an oxygen regulator is pressure reduction. Oxygen stored in cylinders is under very high pressure, often exceeding 2000 psi (pounds per square inch). This high pressure needs to be reduced to a safe and manageable level before it can be used in various applications.

    The regulator reduces the high pressure in two stages:

    • First Stage: This stage reduces the high cylinder pressure to an intermediate level.
    • Second Stage: Further reduces the pressure to the desired output level, which is then delivered to the patient or equipment

    The process relies on the balance between forces inside the regulator: the force exerted by the high-pressure oxygen, the opposing force from a spring, and the control exerted by a diaphragm that adjusts the flow based on demand.

    Key Concepts:

    • Boyle's Law: The principle that the pressure of a gas is inversely proportional to its volume at constant temperature. This is crucial in understanding how regulators adjust pressure.
    • Flow Rate: The amount of oxygen delivered per minute, often measured in liters per minute (L/min). The regulator controls this flow rate, ensuring it remains constant.

    Components of an Oxygen Regulator

    An oxygen regulator consists of several key components, each with a specific function. Here’s a detailed look at these components:

    Pressure Gauge:

    • Function: The pressure gauge measures the pressure inside the oxygen cylinder. It helps users monitor how much oxygen is left and when the cylinder needs to be replaced.
    • Details: Typically, the gauge is marked in psi (pounds per square inch) or kPa (kilopascals). As oxygen is used, the gauge needle moves, indicating the decreasing pressure.

    Diaphragm:

    • Function: The diaphragm is a flexible membrane that responds to pressure changes inside the regulator. It plays a critical role in controlling the flow of oxygen.
    • Details: When the user opens the regulator, the diaphragm adjusts its position based on the pressure differential, allowing oxygen to flow at a controlled rate.

    Valve Assembly:

    • Function: The valve controls the release of oxygen from the high-pressure cylinder to the lower-pressure side. It opens and closes to regulate the amount of oxygen passing through.
    • Details: The valve’s opening is adjusted by the pressure screw or knob on the regulator, which the user turns to increase or decrease the flow.

    Pressure Relief Valve:

    • Function: This safety feature prevents excessive pressure buildup within the regulator. If the pressure exceeds a certain threshold, the relief valve opens to release the excess pressure.
    • Details: This is critical to prevent accidents, such as the regulator or cylinder bursting due to high pressure.

    Flowmeter:

    • Function: The flowmeter measures and displays the flow rate of oxygen being delivered. It allows users to set the precise flow rate needed.
    • Details: Flowmeters are usually calibrated in liters per minute (L/min). Some regulators have an integrated flowmeter, while others use a separate device.

    Types and Applications of Oxygen Regulators

    Oxygen regulators come in various types, each designed for specific applications. Understanding these types and their uses is crucial for selecting the right regulator for a particular situation.

    Single-Stage Regulators:

    • Function: In a single-stage regulator, the pressure reduction from high to low happens in one step.
    • Applications: These are typically used in scenarios where the pressure in the cylinder doesn’t fluctuate significantly or where minor pressure variations are acceptable. They are common in portable medical oxygen systems.
    • Advantages: Simplicity and lower cost make them ideal for less demanding applications.

    Two-Stage Regulators:

    • Function: Two-stage regulators reduce pressure in two steps—first to an intermediate level and then to the desired output level.
    • Applications: Used in situations requiring a more stable and precise flow of oxygen, such as in hospitals or high-altitude aviation.
    • Advantages: They provide more consistent output pressure, which is important in critical applications.

    Continuous Flow Regulators:

    • Function: These regulators provide a steady, continuous flow of oxygen at a set rate.
    • Applications: Common in medical settings for patients requiring constant oxygen, such as in oxygen therapy for chronic obstructive pulmonary disease (COPD) patients.
    • Advantages: Simple operation and reliable for consistent oxygen delivery.

    Demand Flow Regulators (Pulse Dose):

    • Function: These regulators deliver oxygen only when the patient inhales, conserving oxygen and extending the cylinder’s usage time.
    • Applications: Often used in portable oxygen concentrators and for ambulatory patients.
    • Advantages: Efficient oxygen use, making it ideal for portable and home-based oxygen therapy.

    Applications in Various Fields:

    • Medical: Oxygen regulators are vital in emergency care, surgeries, and for patients with respiratory conditions. The type of regulator chosen depends on whether the oxygen needs to be delivered continuously or intermittently.
    • Industrial: Used in welding and cutting processes, where oxygen is required to produce a high-temperature flame. In these settings, two-stage regulators are often preferred for their precision.
    • Aviation: Pilots and passengers in non-pressurized aircraft use oxygen regulators to maintain safe oxygen levels at high altitudes. Demand flow regulators are common here to conserve oxygen.
    • Scuba Diving: Special oxygen regulators are used in rebreathers and other diving equipment to supply breathable air at various depths.

    Troubleshooting and Maintenance

    Maintaining and troubleshooting oxygen regulators is crucial to ensure their reliable operation, especially in critical applications like medical and industrial settings. Here's how to handle these tasks:

    Regular Maintenance:

    • Inspection of Components:
      • Visual Check: Regularly inspect the regulator for any signs of wear, damage, or corrosion. Pay close attention to the pressure gauge, valves, and connections.
      • Leak Test: Periodically perform a leak test by applying soapy water to the regulator connections and watching for bubbles, which indicate a leak.
    • Cleaning:
      • Debris Removal: Keep the regulator clean and free from dust and debris. Use a clean, dry cloth to wipe it down regularly.
      • Oxygen-Safe Lubricants: If needed, only use lubricants that are safe for oxygen systems, as regular oils can be hazardous.
    • Pressure Gauge Calibration:
      • Accuracy Check: Ensure the pressure gauge is calibrated and accurately reflects the cylinder pressure. If it’s off by a significant amount, consider replacing the gauge.

    Troubleshooting Common Issues:

    • Inconsistent Flow or No Flow:
      • Possible Causes: This could be due to a blocked or damaged valve, an empty cylinder, or a malfunctioning diaphragm.
      • Steps to Fix:
        • Check the Cylinder: Ensure there is sufficient oxygen in the cylinder.
        • Inspect the Valve: Look for any obstructions or damage. Cleaning the valve or replacing the diaphragm may be necessary.
        • Regulator Settings: Verify that the flow setting is correct and hasn’t been accidentally adjusted.
    • Leaks:
      • Possible Causes: Leaks can occur at the connections between the cylinder and regulator or within the regulator itself.
      • Steps to Fix:
        • Tighten Connections: Ensure all connections are securely tightened. Use a wrench if necessary.
        • Check Seals and O-Rings: Inspect and replace any worn or damaged seals.
        • Leak Test: After fixing the issue, perform another leak test to confirm the problem is resolved.
    • Pressure Relief Valve Activation:
      • Possible Causes: This could be due to overfilling the cylinder, a malfunctioning regulator, or an obstruction in the flow path causing pressure buildup.
      • Steps to Fix:
        • Release Excess Pressure: Carefully release some pressure from the cylinder if it’s overfilled.
        • Inspect the Regulator: Check for any blockages or damage that might be causing the pressure buildup.
        • Replace the Relief Valve: If the valve itself is faulty, it should be replaced.

    Long-Term Maintenance:

    • Regular Servicing:
      • Professional Inspection: Have the regulator serviced by a qualified technician at regular intervals, especially if it’s used frequently or in critical applications.
      • Replacement Parts: Use only manufacturer-approved parts for any repairs or replacements.
    • Storage:
      • Proper Environment: Store regulators in a clean, dry, and cool place to prevent corrosion and damage.
      • Avoid Contaminants: Keep regulators away from oils, grease, and other contaminants that could react with oxygen.

    Frequently Asked Questions

    How to Deal with Heat from an Aquatuner and Thermo Regulator?

    Managing heat generated by Aquatuners and Thermo Regulators is crucial to maintain an efficient and balanced system. The most effective way to deal with heat is by using thermal management techniques such as building a cooling loop with a dedicated coolant, insulating heated areas, and placing thermal blocks strategically to disperse heat. Additionally, using a combination of Thermo Regulators with controlled automation can help maintain a stable temperature, ensuring your setup runs efficiently without overheating.

    Aquatuner vs. Thermo Regulator: Which is Better for Temperature Management?

    The choice between an Aquatuner and a Thermo Regulator depends on your specific needs. Aquatuners are typically used for cooling large volumes of liquid and are ideal for managing heat in systems with significant temperature variances. Thermo Regulators, on the other hand, are better suited for fine-tuning and maintaining stable temperatures over time. If you need robust cooling, an Aquatuner might be the better choice, whereas a Thermo Regulator is ideal for precision temperature control in smaller setups.

    How to Troubleshoot Issues with Oxygen Regulators?

    If you're experiencing issues with your oxygen regulator, such as insufficient oxygen flow, it's important to first check for leaks and ensure all connections are secure. In cases where a new regulator is not delivering oxygen to your torch, the problem could be due to incorrect installation, a defective regulator, or an incompatible connection. Double-checking the setup according to the manufacturer’s instructions and ensuring the regulator is compatible with your equipment can often resolve these issues. If the problem persists, consider returning the regulator for a replacement.

    Why Is My Thermo Regulator Not Cooling Effectively?

    A Thermo Regulator might not be cooling effectively due to several reasons, such as insufficient coolant, improper installation, or malfunctioning components. First, ensure that the coolant is adequately filled and that there are no blockages in the system. Verify that the Thermo Regulator is correctly configured and that the cooling system is free from leaks or obstructions. Regular maintenance and calibration of the Thermo Regulator can also prevent cooling inefficiencies.

    How Often Should Oxygen Regulators Be Inspected and Maintained?

    Oxygen regulators should be inspected regularly, ideally before each use, to ensure they are functioning properly. Regular maintenance, including checking for leaks, cleaning, and recalibrating, should be done at least annually or as recommended by the manufacturer. Proper maintenance not only ensures optimal performance but also extends the lifespan of your regulator and prevents potential safety hazards.

    What Are the Signs of a Failing Oxygen Regulator?

    Signs of a failing oxygen regulator include inconsistent oxygen flow, difficulty in adjusting pressure, leaks, and unusual noises during operation. If you notice any of these signs, it's important to address the issue immediately to prevent safety risks. Regular inspections can help catch these problems early, and replacing a malfunctioning regulator is critical to ensure safe and efficient operation.

    How to Properly Install an Oxygen Regulator?

    To install an oxygen regulator properly, start by ensuring that the oxygen cylinder valve is closed. Attach the regulator to the cylinder's outlet, ensuring that the connection is tight and secure. Open the cylinder valve slowly while monitoring the regulator's pressure gauge. Adjust the regulator to the desired pressure setting for your application. Always follow the manufacturer's installation instructions to ensure safety and optimal performance.

    Search By Category

    Assisted Living

    Cardiology

    Cosmetic Surgery

    Dentistry

    Dermatology

    Emergency Supplies

    Endoscopy

    ENT (Otolaryngology)

    General Surgery

    Imaging Center

    Medical Furniture

    Medical Instruments

    Medical Lighting

    Medical Supplies

    Orthopedics

    Pediatrics

    Physical Therapy & Chiropractic

    Podiatry

    Surgical Accessories

    Urology

    Veterinary

    Other Medical Equipment

    Service and Repair