The YDS-10 Liquid Nitrogen Container is a high-quality cryogenic vessel designed for the efficient storage and transportation of liquid nitrogen. With a capacity of 10 liters, this container is ideal for laboratories, medical facilities, research institutions, and industrial applications where maintaining cryogenic temperatures is essential. Crafted from durable aluminum alloy, the YDS-10 combines lightweight portability with robust construction. It features advanced vacuum insulation technology, minimizing liquid nitrogen evaporation and ensuring long-term preservation of specimens and materials.
The YDS-10 Liquid Nitrogen Container is used for:
-
Biological Sample Storage: Preserving biological specimens such as cells, tissues, sperm, embryos, and vaccines at cryogenic temperatures.
-
Medical Applications: Cryosurgery, dermatology treatments, and other medical procedures requiring liquid nitrogen.
-
Industrial Applications: Shrink-fitting of metal components, cryogenic processing, and cold treatment of metals.
-
Scientific Research: Experiments and processes that require extremely low temperatures.
Instructions for Use:
-
Preparation:
- Ensure the container is clean and dry before use.
- Inspect for any signs of damage or wear.
-
Filling the Container:
- Fill slowly to prevent rapid temperature changes that can stress the container.
- Use appropriate personal protective equipment (PPE), including cryogenic gloves and face protection.
- Handling and Transportation:
- Carry the container using the handle provided.
- Keep the container upright at all times to prevent spillage.
- Secure the container during transport to prevent tipping.
- Storage:
- Store in a well-ventilated area to prevent nitrogen gas accumulation.
- Keep away from heat sources and direct sunlight.
- Maintenance:
- Regularly check the liquid nitrogen levels.
- Do not seal the container airtight; pressure buildup can cause hazards.
- Clean with a soft cloth; avoid abrasive materials.
- Benefits
- High Capacity: Ample 10-liter volume reduces the need for frequent refilling.
- Efficient Insulation: Vacuum insulation technology minimizes evaporation rates, extending holding times.
- Durable Construction: Aluminum alloy body resists corrosion and withstands harsh environments.
- Lightweight and Portable: Easy to handle and move, even when full.
- Versatile Applications: Suitable for medical, scientific, industrial, and veterinary uses.
- Safety Features: Pressure-relief design prevents pressure buildup; secure lid reduces spillage risks.
- Cost-Effective: Low nitrogen loss saves costs over time.
Specialty / Medical Practice: Dermatology, Plastic Surgery, Gynecology, Food Industry, Medical Laboratory and more
Specifications:
- Product Usage: Safe Storage of liquid nitrogen
- Brand: YDS
- Dimensions:
- Days to be ready: 1-2
Related Collections:
-
Liquid Nitrogen Storage Tanks
- Procedure Chairs
- OBGYN
- Dentistry
- Cosmetic Surgery
Frequently Asked Questions (FAQs) and Answers
What is the capacity of the YDS-10 Liquid Nitrogen Container?
The YDS-10 has a capacity of 10 liters of liquid nitrogen.
How long can the YDS-10 hold liquid nitrogen before it evaporates?
The container has a static holding time of approximately 60 days, depending on ambient conditions and usage frequency.
What are the dimensions and weight of the container?
Dimensions: Approximately 55 cm (21.6 inches) in height and 30 cm (11.8 inches) in diameter.
Empty Weight: Around 6 kg (13.2 lbs).
Can I store biological samples directly in the container?
Yes, it comes with individual canisters or racks for holding biological samples like vials or straws.
Is the YDS-10 suitable for transporting liquid nitrogen?
Yes, it's designed for both storage and transportation. However, during transport, it should be kept upright and secured to prevent tipping.
What safety precautions should I take when using this container?
Use appropriate PPE: Cryogenic gloves, face shield, and protective clothing.
Ensure adequate ventilation to prevent nitrogen gas buildup.
Do not seal the container airtight; allow for pressure release.
How do I fill the YDS-10 with liquid nitrogen?
Fill slowly using a transfer tube or funnel designed for cryogenic liquids to prevent splashing and thermal shock.
Can the container be used for liquid oxygen or other cryogenic liquids?
No, the YDS-10 is specifically designed for liquid nitrogen. Using it with other cryogenic liquids can be hazardous.
How do I check the liquid nitrogen level inside the container?
Use a cryogenic dipstick or measure by weight difference. Some users also use a wooden stick that frosts up to indicate the level.
What is the evaporation (loss) rate of the container?
The normal evaporation rate is about 0.098 liters/day, but this can vary based on environmental factors.
Does the container require any maintenance?
Minimal maintenance is required. Keep it clean, dry, and inspect regularly for damage. Avoid dropping or impacting the container.
Is the YDS-10 compliant with safety standards and regulations?
Yes, it meets international safety standards for cryogenic containers. Always verify compliance with local regulations.
Can I lay the container on its side during transportation?
No, the container must remain upright to prevent spillage and maintain insulation integrity.
Does the YDS-10 come with a warranty?
Warranty terms vary by supplier, but typically, it includes a one-year limited warranty against manufacturing defects.
How do I safely dispose of or recycle the container at the end of its life?
Contact the manufacturer or local waste management services for proper disposal guidelines, as it may require special handling.
Where can I purchase replacement parts or accessories for the YDS-10?
Replacement parts, such as lids or canisters, and accessories can be purchased through the manufacturer.