Labconco purifier Biosafety Cabinet (Used)

Lobconco SKU: LAEQ-048444
Labconco purifier Biosafety Cabinet (Used) Image 1
Labconco purifier Biosafety Cabinet (Used) Image 2
Labconco purifier Biosafety Cabinet (Used) Image 3
Labconco purifier Biosafety Cabinet (Used) Image 4
Labconco purifier Biosafety Cabinet (Used) Image 5
Labconco purifier Biosafety Cabinet (Used) Image 6
Labconco purifier Biosafety Cabinet (Used) Image 7
Labconco purifier Biosafety Cabinet (Used) Image 8
Labconco purifier Biosafety Cabinet (Used) Image 9

Labconco purifier Biosafety Cabinet (Used)

Lobconco SKU: LAEQ-048444
No reviews
Note:- This item requires freight shipping, in order to provide you with the best rates, we have to contact and acquire shipping cost from multiple freight companies. The shipping is set to local pickup which is free, however you will be charged in another invoice for the shipping cost once we have it. Please contact us directly for additional questions.
Regular price $4,500.00 Sale price $3,950.00 Save $550
/
  • Secure payments
  • Low stock - 1 item left
  • Inventory on the way
Please check the acknowledgement box and confirm that you have read and understood the message before proceeding with your purchase.
Shipping calculated at checkout.

Labconco purifier Class II Biosafety cabinet GS-010 Delta series is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.

The primary purpose of a BSC is to serve as a means to protect the laboratory worker and the surrounding environment from pathogens. All exhaust air is HEPA-filtered as it exits the biosafety cabinet, removing harmful bacteria and viruses. This is in contrast to a laminar flow clean bench, which blows unfiltered exhaust air towards the user and is not safe for work with pathogenic agents. Neither are most BSCs safe for use as fume hoods. Likewise, a fume hood fails to provide the environmental protection that HEPA filtration in a BSC would provide. However, most classes of BSCs have a secondary purpose to maintain the sterility of materials inside (the "product").

Class II cabinets provide both kinds of protection (of the samples and of the environment) since makeup air is also HEPA-filtered. There are five types: Type A1 (formerly A), Type A2 (formerly A/B3), Type B1, Type B2 and Type C1. Each type's requirements are defined by NSF International Standard 49, which in 2002 reclassified A/B3 cabinets (classified under the latter type if connected to an exhaust duct) as Type A2, and added the Type C1 in the 2016 standard. About 90% of all biosafety cabinets installed are Type A2 cabinets.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Sale
Labconco purifier Biosafety Cabinet (Used) Labconco purifier Biosafety Cabinet (Used) Image 1
Labconco purifier Biosafety Cabinet (Used)
Lobconco
Sale price $3,950.00 Regular price $4,500.00 Save $550
Recently viewed