Description
This unit is certified, calibrated and fully functional.
Ellman Surgitron 4.0 dual RF Cart Tower System
The Ellman Surgitron® 4.0 Dual RF 120 is a high‑frequency radiofrequency (RF) surgical generator designed for cutting, coagulation, and hemostasis of soft tissue—delivering RF output controlled by front‑panel settings and activated via foot and/or hand switch (with both monopolar and bipolar electrodes)
Paired with the Surg‑e‑Vac™ smoke evacuation system, this full tower setup supports clearer visualization by drawing smoke plume away from the operatory field while helping reduce smoke odor.
Deliver clean, precise soft-tissue cutting and coagulation with 4.0 MHz radiosurgery—then keep the field clear with integrated smoke evacuation. The Surgitron® Dual RF 120 platform pairs Monopolar 4.0 MHz with Bipolar 1.7 MHz for control, while the Surg‑e‑Vac™ supports visibility by removing surgical plume
Technology: Dual Frequency RF — Monopolar 4.0 MHz / Bipolar 1.7 MHzMax output power: 120 W (generator)Generator dimensions: 7.1" × 9.5" × 16.5 nbsp;Generator weight: 19 lbSmoke evacuation: Described with 150 ft/min inlet velocity at the wand tip and multi‑filtration designSurg‑e‑Vac filtration (listed): Filters microorganisms 0.12 microns at 99.999% efficiency (as described by a supplier listing)What’s included (tower listing): Surgitron® 4.0 Dual RF 120 IEC + Surg‑e‑Vac + foot pedal + handpiece + grounding plate + smoke evac filter + car
Key Benefits
Precision tissue effect
- Dual Frequency control: Monopolar 4.0 MHz plus Bipolar 1.7 MHz for control and versatility across technique needs.
- Less thermal spread : Manufacturer marketing cites 73% less thermal spread versus specific conventional electrosurgical generators in porcine tissue.
- Cosmetic and healing advantages: Marketed benefits include minimal scar tissue, excellent cosmetic results, quick recovery, and decreased post‑operative pain.
Visibility & plume management (Surg‑e‑Vac)
- Better visibility: Removes smoke plume from the operatory area to improve visibility.
- Plume odor reduction: Described as eliminating unpleasant smoke plume odors.
- Airflow spec : Inlet velocity of 150 feet per minute at the wand tip
Workflow & usability
-
Digital control panel + parameter recall: Designed for clear settings visibility and rapid repeat setup.
-
Safety indicators: Visual and auditory alerts are listed among features.
Typical Uses / Specialties
Indications (regulatory summary): Intended to deliver electrosurgical output to perform cutting, coagulation, and hemostasis of soft tissues, and to heat tissue in certain non‑ablative aesthetic indications (as stated in a 510(k) summary).
Common procedures listed in product materials include (examples):
- Biopsy for pathology, bipolar coagulation, blepharoplasty, endoscopic brow lift, epilation, face-lifts, flaps & grafts, lesion removal, matrixectomy, Mohs surgery, rhinophyma, scar revision, telangiectasia, wart removal
Note: Specific clinical applications depend on clinician training, electrode selection, and local regulations; always follow official IFUs and facility protocols.
Specifications
Surgitron® 4.0 Dual RF 120 (Generator)
-
Dimensions: 7.1" (H) × 9.5" (W) × 16.5" (D)
-
Weight: 19 lb
-
Line voltage: 100–240V, 50/60 Hz
-
Operating frequencies: 4.0 MHz (Monopolar) / 1.7 MHz (Bipolar)
-
Output power (listed):
- Monopolar Cut: 120 W
- Monopolar Blend: 90 W
- Monopolar Coag: 60 W
- Monopolar Fulgurate: 45 W
- Bipolar: 120 W
Surg‑e‑Vac™ Smoke Evacuator
- Inlet velocity: 150 ft/min at wand tip (as described)
- Filtration claim (listed by supplier): Filters microorganisms >0.12 microns at 99.999% efficiency
- Control/activation (listed): Variable suction speed control with multiple settings; foot pedal & finger control activation
Cart (Tower system)
The ellman Surgitron is normally configured and sold as a full tower including a dedicated cart with the generator and smoke evacuator.
What’s Included (Full Tower System)
A tower configuration is shown/listed to include:
- Surgitron® 4.0 Dual RF 120 IEC generator
- Surg‑e‑Vac smoke evacuator
- Foot pedal / foot‑pedal activation
- Handpiece
- Grounding plate
- Smoke evac filter
- Proprietary cart
Why 4.0 MHz Matters
The Surgitron® platform is marketed around high-frequency 4.0 MHz RF to minimize unwanted heat dissipation and support controlled tissue effects compared with conventional electrosurgery, with manufacturer materials highlighting reduced thermal spread and improved cosmetic outcomes.
Related Collections:
Frequently Asked Questions
1) What does “Dual RF” mean on the Surgitron® 4.0?
It refers to two optimized RF frequencies—4.0 MHz monopolar and 1.7 MHz bipolar—available in one generator to support precision and control across different techniques.
2) What procedures is the Surgitron® 4.0 Dual RF intended for?
Regulatory documentation describes intended use for cutting, coagulation, and hemostasis of soft tissue, with additional stated indications involving tissue heating for certain non-ablative aesthetic treatments.
3) What are the generator’s dimensions and weight?
The generator is listed at 7.1" H × 9.5" W × 16.5" D and 19 lb.
4) What power output can I expect?
Listed outputs include up to 120 W in Monopolar Cut and 120 W in Bipolar, with additional waveform-specific outputs (Blend, Coag, Fulgurate) as specified in product literature.
5) Why add a smoke evacuator like Surg‑e‑Vac?
Smoke evacuation supports better visibility by removing plume from the operatory area and is described as helping reduce unpleasant smoke odors.
6) How strong is the Surg‑e‑Vac airflow?
One product listing describes 150 ft/min inlet velocity at the wand tip, designed to capture plume close to the source.
7) What filtration performance is claimed for Surg‑e‑Vac?
A supplier listing states filtration for microorganisms larger than 0.12 microns at 99.999% efficiency.
8) Is this sold as a complete tower with a cart?
Some listings show a full tower system that includes the Surgitron® generator, Surg‑e‑Vac, accessories, and a dedicated cart.